EnvelopePower

SCPI Commands :

CONFigure:GPRF:MEASurement<Instance>:POWer:LIST:ENPower
CONFigure:GPRF:MEASurement<Instance>:POWer:LIST:ENPower:ALL
class EnvelopePowerCls[source]

EnvelopePower commands group definition. 2 total commands, 0 Subgroups, 2 group commands

get(index: int) float[source]
# SCPI: CONFigure:GPRF:MEASurement<Instance>:POWer:LIST:ENPower
value: float = driver.configure.power.listPy.envelopePower.get(index = 1)

Defines or queries the expected nominal power of segment <Index>.

param index:

integer Range: 0 to 3999

return:

exp_nom_power: numeric The range of the expected nominal power can be calculated as follows: Range (Expected Nominal Power) = Range (Input Power) + External Attenuation - User Margin The input power range is stated in the data sheet. Unit: dBm

get_all() List[float][source]
# SCPI: CONFigure:GPRF:MEASurement<Instance>:POWer:LIST:ENPower:ALL
value: List[float] = driver.configure.power.listPy.envelopePower.get_all()

Defines the expected nominal power for all segments.

return:

exp_nom_power: numeric Comma-separated list of expected powers, one value per segment The range of the expected nominal power can be calculated as follows: Range (Expected Nominal Power) = Range (Input Power) + External Attenuation - User Margin The input power range is stated in the data sheet. Unit: dBm

set(index: int, exp_nom_power: float) None[source]
# SCPI: CONFigure:GPRF:MEASurement<Instance>:POWer:LIST:ENPower
driver.configure.power.listPy.envelopePower.set(index = 1, exp_nom_power = 1.0)

Defines or queries the expected nominal power of segment <Index>.

param index:

integer Range: 0 to 3999

param exp_nom_power:

numeric The range of the expected nominal power can be calculated as follows: Range (Expected Nominal Power) = Range (Input Power) + External Attenuation - User Margin The input power range is stated in the data sheet. Unit: dBm

set_all(exp_nom_power: List[float]) None[source]
# SCPI: CONFigure:GPRF:MEASurement<Instance>:POWer:LIST:ENPower:ALL
driver.configure.power.listPy.envelopePower.set_all(exp_nom_power = [1.1, 2.2, 3.3])

Defines the expected nominal power for all segments.

param exp_nom_power:

numeric Comma-separated list of expected powers, one value per segment The range of the expected nominal power can be calculated as follows: Range (Expected Nominal Power) = Range (Input Power) + External Attenuation - User Margin The input power range is stated in the data sheet. Unit: dBm