Current
SCPI Commands :
FETCh:GPRF:MEASurement<Instance>:FFTSanalyzer:POWer:CURRent
READ:GPRF:MEASurement<Instance>:FFTSanalyzer:POWer:CURRent
- class CurrentCls[source]
Current commands group definition. 2 total commands, 0 Subgroups, 2 group commands
- fetch() List[float] [source]
# SCPI: FETCh:GPRF:MEASurement<Instance>:FFTSanalyzer:POWer:CURRent value: List[float] = driver.fftSpecAn.power.current.fetch()
Returns the traces of the spectrum diagram. The current, average, minimum and maximum traces can be retrieved. Each trace contains 801 power values and covers the configured frequency span.
Use RsCmwGprfMeas.reliability.last_value to read the updated reliability indicator.
- return:
power: float Comma-separated list of 801 power values Unit: dBm
- read() List[float] [source]
# SCPI: READ:GPRF:MEASurement<Instance>:FFTSanalyzer:POWer:CURRent value: List[float] = driver.fftSpecAn.power.current.read()
Returns the traces of the spectrum diagram. The current, average, minimum and maximum traces can be retrieved. Each trace contains 801 power values and covers the configured frequency span.
Use RsCmwGprfMeas.reliability.last_value to read the updated reliability indicator.
- return:
power: float Comma-separated list of 801 power values Unit: dBm