Minimum
SCPI Commands :
CALCulate:GPRF:MEASurement<Instance>:POWer:PEAK:MINimum
FETCh:GPRF:MEASurement<Instance>:POWer:PEAK:MINimum
READ:GPRF:MEASurement<Instance>:POWer:PEAK:MINimum
- class MinimumCls[source]
Minimum commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- calculate() List[ResultStatus2] [source]
# SCPI: CALCulate:GPRF:MEASurement<Instance>:POWer:PEAK:MINimum value: List[enums.ResultStatus2] = driver.power.peak.minimum.calculate()
- Returns power results for all segments, see ‘Results in list mode’.
INTRO_CMD_HELP: The following results can be retrieved:
‘Current RMS’ (…:POWer:CURRent?)
‘Current Min.’ (…:MINimum:CURRent?)
‘Current Max.’ (…:MAXimum:CURRent?)
‘Average RMS’ (…:AVERage?)
‘Minimum’ (…:PEAK:MINimum?)
‘Maximum’ (…:PEAK:MAXimum?)
‘Standard Deviation’ (…:SDEViation?)
The values described below are returned by FETCh and READ commands. CALCulate commands return error codes instead, one value for each result listed below.
Use RsCmwGprfMeas.reliability.last_value to read the updated reliability indicator.
- return:
power_minimum_min: float Comma-separated list of power values, one value per measured segment Unit: dBm (SDEViation: dB)
- fetch() List[float] [source]
# SCPI: FETCh:GPRF:MEASurement<Instance>:POWer:PEAK:MINimum value: List[float] = driver.power.peak.minimum.fetch()
- Returns power results for all segments, see ‘Results in list mode’.
INTRO_CMD_HELP: The following results can be retrieved:
‘Current RMS’ (…:POWer:CURRent?)
‘Current Min.’ (…:MINimum:CURRent?)
‘Current Max.’ (…:MAXimum:CURRent?)
‘Average RMS’ (…:AVERage?)
‘Minimum’ (…:PEAK:MINimum?)
‘Maximum’ (…:PEAK:MAXimum?)
‘Standard Deviation’ (…:SDEViation?)
The values described below are returned by FETCh and READ commands. CALCulate commands return error codes instead, one value for each result listed below.
Use RsCmwGprfMeas.reliability.last_value to read the updated reliability indicator.
- return:
power_minimum_min: float Comma-separated list of power values, one value per measured segment Unit: dBm (SDEViation: dB)
- read() List[float] [source]
# SCPI: READ:GPRF:MEASurement<Instance>:POWer:PEAK:MINimum value: List[float] = driver.power.peak.minimum.read()
- Returns power results for all segments, see ‘Results in list mode’.
INTRO_CMD_HELP: The following results can be retrieved:
‘Current RMS’ (…:POWer:CURRent?)
‘Current Min.’ (…:MINimum:CURRent?)
‘Current Max.’ (…:MAXimum:CURRent?)
‘Average RMS’ (…:AVERage?)
‘Minimum’ (…:PEAK:MINimum?)
‘Maximum’ (…:PEAK:MAXimum?)
‘Standard Deviation’ (…:SDEViation?)
The values described below are returned by FETCh and READ commands. CALCulate commands return error codes instead, one value for each result listed below.
Use RsCmwGprfMeas.reliability.last_value to read the updated reliability indicator.
- return: